GEOMICS Services ,Laser Tracker Services, FARO Laser Tracker, SMX Laser Tracker, Leica, API ,Laser Tracker Calibration, Web Hosting, Web Design, Corporate Websites, Product Design, Product Development, Design Development Manufacture. Web development, Tracker Calibration, Dimensional Metrology, Industrial Metrology consulting, 3D measurement services
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Laser Tracker Calibration
Item number: LTC-003-001


DESCRIPTION..

The SMX Laser Tracker 4000/4500 series require an annual calibration to ensure system accuracy. The laser tube inside the Tracker head is a primary standard that does not require calibration. However the environmental sensors (temperature and pressure) are very important to ensure the system calculates the correct wavelength of light when measuring.

Re-Calibration consists of a complete system cleaning to remove the build-up of matter from the cooling system and environmental sensors. These sensors are then tested and adjusted to primary standards that are NIST traceable. We then Tune the system to improve tracking performance and reduce down-time. Finally tracker compensations are run to ensure total tracker performance and accuracy.

Laser Tracker Calibration

 

 

 

 

 

 

FEATURES..
  • Express Tracker Re-Certification can be performed ON-SITE in 1 day to reduce down-time.
  • Normal Re-Certifications are performed in the UK Service Centre. Allow 2 days shipping + I day Calibration.
  • Increase tracker performance, accuracy and ensure your measurements are correct.
  • Calibrated to the highest Standard using Druck DPI 740 Pressure and YSI 4600S Temperature standards.
  • Certificates of calibration are shipped with tracker and uploaded to internet for viewing and printout.
  • Important system files from TCU are backed up to the internet and can be downloaded in event of a failure.

 

VIEW EXAMPLE CALIBRATION CERTIFICATE
 

 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------BACK TO TOP▲


TECHNICAL DATA..

Temperature Standard YSI 4600S Precision Thermometer accuracy ± 0.020% FS
Pressure Standard Druck DPI740 Absolute Pressure Gauge accuracy ± 0.025°C
Calibration Time ON-SITE 1 day (approximately 8 hours)
  UK Service Centre 1 day for calibration + 2 days return shipping.
Calibration information Certificate of Calibration Shipped with tracker & uploaded to Geomics web server
  TCU System data Backed up to Geomics web server

All specifications are subject to change without notice.
 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------BACK TO TOP▲
 

PRINT  BROCHURE..
PRINT BROCHURE DOWNLOAD ACROBAT READER
PDF Logo Get Acrobat logo
 

 

 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------BACK TO TOP▲


VIDEO..

No Video data available for this product.

 

 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------BACK TO TOP▲

 


IMAGE GALLERY..

No images at this time.

 

 ------------------------------------------------------------------------------------------------------------------------------------------------------ --------------------------------------------------------------------------BACK TO TOP▲

GEOMICS ,Laser Tracker Services, FARO Laser Tracker, SMX Laser Tracker, Leica, API ,Laser Tracker Calibration, Web Hosting, Web Design, Corporate Websites, Product Design, Product Development, Design Development Manufacture. Web development, Tracker Calibration, Dimensional Metrology, Industrial Metrology consulting, 3D measurement services

Created by GEOMICS Limited. Copyright © 2003. All rights reserved. Revised: 01/30/08